Automatic Wrist Blood Pressure Devices for Clinical Use and also suitable
for home/self assessment

Wrist devices are subject to errors that are not presently evaluated in the available validation protocols. The most important source of error with wrist devices is the position of the arm in relation to the heart. A wrist device may fulfil the accuracy criteria of a validation protocol when strict attention is paid to having the wrist at heart level but in home use this may not happen and as a consequence the measurements can become inaccurate. For this reason validated upper arm devices are recommended in preference to wrist devices.

Device / Grade

Cost (rrp) (incl VAT)

Cuff sizes (cm)

Weight (g)

Dimensions
(l x w x h, mm)

Number/type of batteries

Omron R62
Derivative of 637-IT
International Protocol
£99.95
(Feb 08)
Fits 13.5 - 21.5 110 70 x 54 x 37 2 x AAA Alkaline
Omron 637-IT1
(R7 HEM-637-E2 [EU])
Also validated for use in obese adults and the elderly see 'BP Devices for use in special cases'
International Protocol
£149.95
(Feb 08)
Fits 13.5 - 21.5 165 79 x 66.5 x 38 2 x AAA Alkaline
Omron R72
(HEM-637- IT)
International Protocol
£119.95
(Feb 08)
Fits 13.5 - 21.5 150 78 x 65.5 x 37.2 2 x AAA Alkaline
Oregon Sientific BPW8103
International Protocol
£99.00 Fits 13.5 - 21.5 180 without batteries 90 x 86 x 30.8 2 x AAA Alkaline

Distributors

Omron Healthcare (UK) Limited
Opal Drive
Fox Milne,
Milton Keynes
MK15 0DG
Tel: 0870 750 2771
Fax: 0870 750 2772
Email: info.omronhealthcare.uk@eu.omron.com
Web: www.omron-healthcare.com

Oregon Scientific UK
Unit 1, Switchback Gardner Rd
Maidenhead
Berkshire
SL6 7RJ
Tel: 0845 6013964

References 

  1. Altunkan S, Oztas K, Altunkan E. Validation of the Omron 637IT wrist blood pressure measuring device with a position sensor according to the International Protocol in adults and obese adults. Blood Pressure Monitoring 2006, 11 (2): 79-85

  2. Topouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN & Asmar RG. Validation of two automatic devices for self- measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT). Blood Pressure Monitoring 2006, 11(3): 165-171

  3. Li Li, Wang Hui and Wu Jin Lan. Validation of the Oregon Scientific BPW810 blood pressure monitor according to the European Society of Hypertension Protocol. Blood Pressure Monitoring 2006,11: 343-347

Download Adobe Acrobat  Download Adobe Acrobat