Device/ Grade Cost (rrp) (incl VAT) Cuff sizes (cm) Weight (g) Dimensions
(l x w x h, mm)
Number/type of batteries
Greenlight 3001
International Protocol
£136
(Jun 2005)
Max Limb Circumference Standard adult 34.3 (included)
Alternative adult 42
Outsize adult 48.2
Child 26.6
Young child 21.8
Infant 17.3
Newborn 12.2
Thigh 60.9

New Sizes
Child 26
Small Child 17
650 250 x 170 x 100 4 x AA
Nissei DM 30004
Auscultatory and oscillometric function
£292.58 Standard Adult included
Large Adult included
1000g
 incl cuff container
136 x 206 x 276 Rechargeable battery pack
AC Mains adapter included
Omron 9072,3
Same as HEM 907
See also 'Automatic BP devices for Clinical Use'
International Protocol
£350.95
(Feb 2008)
Small adult (17-22)
Standard adult (22-32)
Large adult (32-42)
910 203 x 139 x 131 AC Adapter (with battery pack)

Go to the archive for a list of discontinued approved devices
(NB there are no discontinued approved manual devices for clinical use listed)

Distributors

A C Cossor & Son (Surgical) Ltd
Accoson Works
Vale Rd
London
N4 1PS
Tel: 020 8800 1172
Fax: 020 8809 5170
Email: accoson@accoson.com
Web: http://www.greenlight300.com/

Nissei Healthcare (UK) Ltd
Rede House
New Barn Lane
Henfield
West Sussex
BN5 9SJ
Tel: 01273 4955234
E-mail: nisseihealthcare@btconnect.com
Website: www.nisseihealthcare.com

Omron Healthcare (UK) Limited
Opal Drive
Fox Milne
Milton Keynes
MK15 0DG
Tel: 0870 750 2771
Fax: 0870 750 2772
E-mail: info.omronhealthcare.uk@eu.omron.com
Website: www.omron-healthcare.com

References

  1. Graves, JW, Tibor, M, Blaithnead, M, Klein, L & Sheps, SG. The Accoson Greenlight 300, the first non-atomated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults.
    Blood Pressure Monitoring 2004, 9 (1), 13-17

  2. William B. White and Yusra Anis Anwar. Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults. Blood Pressure Monitoring, 2001; 6:107-110.

  3. Mohammed A El. Assaad, Jirar A Topouchian, Bernadette M. Darne and Roland G. Asmar. Validation of the Omron HEM-907 device for blood pressure measurement. Blood Pressure Monitoring, 2002; 7:237-241

  4. Original validation data reviewed by the BHS Blood Pressure Measurement Working Party and approved.