Manufacturer
|
Model
|
Protocol
|
Study Ref (see below)
|
|
A&D
|
*UA-778
Validated for use in children
|
BHS B/A AAMI
|
12 |
|
Andon |
KD-391 |
ESH International Protocol Pass
|
13 |
|
Andon |
KD5915 |
ESH International Protocol Pass
|
21 |
|
Artsana |
CSI610 |
ESH International Protocol Pass
|
1 |
|
BTL |
BTL-08 ABPM II
OEM version of Meditech ABPM-05
|
BHS B/B |
11 |
|
ET Medical Devices SPA |
Cardioline Walk200B, OEM Derivative of IEM Mobil-o-Graph |
ESH International Protocol Pass
BHS A/A |
24,
25 |
|
Hartmann |
Tensoval
Duo Control |
ESH International Protocol Pass
BHS A/A AAMI
|
8 |
|
Health & Life |
HL 168JD Wrist monitor |
ESH International Protocol Pass
|
16 |
|
Health & Life |
HL 168KB
Derivative of Health & Life
HL168JD |
ESH International Protocol Pass
|
16 |
|
Health & Life |
HL 868BA |
ESH International Protocol Pass
|
2 |
|
Health & Life |
*HL868NF Derivative of Health & Life
HL888HA |
BHS A/A |
10 |
|
Health & Life |
*HL868ZA Derivative of Health & Life HL888HA |
BHS A/A |
10 |
|
Health & Life |
*HL868ZB Derivative of Health & Life HL888HA |
BHS A/A |
10 |
|
Health & Life |
*HL888HC Derivative of Health & Life HL888HA |
BHS A/A |
10 |
|
HoMedics |
WGNBPA-540 |
AAMI |
29 |
|
Kingyield |
BP101H |
ESH International Protocol Pass |
22 |
EnviteC-Wismar GmbH
a Honeywell Company
|
*PhysioQuant
Ambulatory device oscillometric Mode
|
ESH International Protocol Pass
|
14 |
|
Medipro/Rossmax |
Medicare 100f |
ESH International Protocol Pass |
28 |
|
Medisana |
MTP Plus |
ESH International Protocol 2010 Pass |
26 |
|
Medset Medizintechnik GmbH |
Scanlight III ABPM, OEM Derivative of IEM Mobil-o-Graph |
ESH International Protocol Pass
BHS A/A |
24, 25 |
|
Omron |
HEM-711 DLX |
ESH International Protocol Pass
|
3 |
|
Omron |
HEM-SOLAR (HEM-4500-SOLE) derivative of Omron M1 Plus (HEM-4011C-E) |
ESH International Protocol Pass |
19 |
|
Omron |
M1 Compact (HEM-4022-E)
Derivative of M1 Plus (HEM-4011C-E) |
ESH International Protocol Pass
|
19 |
|
Omron |
R3-I Plus (HEM-6022-E)
Wrist Monitor |
ESH International Protocol Pass
|
20 |
|
Rossmax **Also branded as Accumed
|
*ME701 and derivative devices: AB701, AC701, AD701, AE701, **AF701, AJ701, MJ701,
MW701, MA801, MR801,MV801, AD761, AK150, MG150, AU941, MW821, **AW150, **MA350,
MC100, MJ150, MR250, MH150, AC 761f
, **AT150, **AV151. **AV351,
**MH901 |
BHS A/A ESH International Protocol Pass
|
4 |
|
Seagull aps |
*S-888HA Derivative of Health & Life HL888HA |
BHS A/A |
10 |
|
Seagull aps |
*S-868BA Derivative of Health & Life HL868BA |
ESH International Protocol Pass
|
2 |
|
Seagull Healthcare |
*888EA Derivative of Health & Life HL888HA |
BHS A/A |
10 |
|
Sensacare |
SAA-102 |
ESH International Protocol Pass
BHS A/A
|
5 |
|
Sensacare |
SAW102 |
BHS B/B
ESH International Protocol Pass
AAMI |
17 |
|
Spengler |
Pro M |
ESH International Protocol Pass
|
6 |
|
Spengler |
TB-101 and SMS-Pro both derivative of KP-7500D |
ESH International Protocol Pass
|
7 |
|
UEBE |
Visomat Comfort
|
ESH International Protocol Pass
|
15 |
|
UEBE |
Visomat Comfort Eco |
ESH International Protocol Pass
|
9 |
|
UEBE |
Visomat Double Comfort
Auscultatory mode only |
ESH
International
Protocol
Pass |
27 |
|
UEBE |
Visomat Handy Wrist Device |
ESH International Protocol Pass
|
23 |
|
Visocor |
HM40 |
ESH International Protocol Pass
|
18 |
* Minor Protocol violation; only 2 observers used in the validation study
References
- Pini C, Pastori M, Baccheschi J, Omboni S & Parati G. Validation of the Artsana
CSI 610 automated blood pressure monitor in adults according to the International
Protocol of the European Society of Hypertension. Blood Pressure Monitoring 2007,
12:179-184
- Chen HE, Cui Y, Sheng CS, Li LH, Li Y, Wang JG. Validation of the Health & Life
HL868BA blood pressure monitor for home blood pressure monitoring according
to the European Society of Hypertension International Protocol. Blood Pressure Monitoring
2008, 13:305-308
- Grim C, Grim C. Omron HEM-711 DLX home blood pressure monitor passes the European
Society of Hypertension International Validation Protocol. Blood Pressure Monitoring
2008. 13:225-226
- de Greeff A, Shennan AH, The Rossmax (ME 701 Series) upper arm device: accuracy
assessment in an adult population according to the International and the British
Hypertension Society protocols. Blood Pressure Monitoring 2008, 13:43-48
- Zaetta V, Daniele L, Perkovic D, Prattico F, Barisa M, Perfetti P, Gabrieli A, Buonocore
F, Winnicki M. Validation of the SAA-102 home blood pressure monitor according to the protocols
of the European Society of Hypertension, the Association for the Advancement of Medical
Instrumentation and the British Society of Hypertension. Blood Pressure
Monitoring 2007, 12:363-368
- de Greef A, Ahmed N, Sheppard E, Shennan A. A self-measurement device suitable for
hospital use: validation of the Spengler Pro M according to the International Protocol
of the European Society of Hypertension. Blood Pressure Monitoring 2008, 13:183-186
- Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol
of the European Society of Hypertension. Vascular Health and Risk Management 2007:3(4),
1-12
- De Greeff A, Arora J, Hervey S, Liu B & Shennan AH. Accuracy assessment of the
Tensoval duo control according to the British and European Hypertension Societies’
standards. Blood Pressure Monitoring 2008, 13:111-116
- D Perkovic, C Guarnieri & P Palatini. Validation of the visomat comfort eco
blood pressure measuring device according to the International Protocol. Blood Pressure
Monitoring 2009, 14:178-180
- de Greeff, Shennan AH. The Health and Life device (HL888HA): accuracy assessment
in an adult population according to the British Hypertension Society Protocol. Blood
Pressure Monitoring 2007, 12:107-111
- Barna HM Keazei A, Dunai A. Evaluation of Meditech ABPM-04 ambulatory blood pressure
measuring device according to the British Hypertension Society protocol. Blood Pressure
Monitoring 1998; 3: 363-368
- Narogan MV, Narogan MI, Syutkina EV. Validation of A&D UA-778 blood pressure
monitor in children. Blood Pressure Monitoring 2009, 14:228-231
- Wan Y, Pan F, Liu Y, Liang Y, Yang Y, Zhao H and Xu Y. Validation of the Andon KD-391
semiautomated blood pressure monitor in adults according to the International Protocol.
Blood Pressure Monitoring 2009, 14:181-184
- Langewitz W and Tanner S. Validation of the PhysioQuant blood pressure measuring
monitor in adults. Blood Pressure Monitoring 2009, 00:000-000
- Bonso E, Dorigatti F, Saladini F, Palatini P. Validation of the Visomat Comfort
form device for home blood pressure measurement according to the International Protocol.
Blood Pressure Monitoring 2010, 15(1):63-66
- C Sheng, Q Huang, J Wang, Y Zhang, Y Li and J Wang. Validation of the Health &
Life HL 168JD wrist blood pressure monitor for home blood pressure monitoring according
to the International Protocol. Blood Pressure Monitoring 2009, 14:125-127
- V Zaetta, D Longo, D Perkovic, P Perfetti, A Gabrieli, F Prattico and M Winnicki.
Validation of the SAW-102 wrist home blood pressure monitor according to the protocols
of the British Hypertension Society, the Association for the Advancement of Medical
Instrumentation and the European Society of Hypertension. Blood Pressure Monitoring
2009, 14:32-36
- F Dorigatti, E Bonso, F Saladini and P Palatini. Valdiation of the Visocor HM 40
wrist blood pressure measuring device according to the International Protocol. Blood
Pressure Monitoring 2009, 14:83-86
- Belghazi J, El Feghali RN, Moussalem t, Rejdych M, Asmar RG. Validation of four
automatic devices for self-measurement of blood pressure according to the International
Protocol of the European Society of Hypertension. Vascular Health & Risk Management
2007, 3(4):389-400
- Asmar R, Khabouth J, Topouchian J, El Feghali R, Mattar J. Validation of three automatic
devices for self-measurement of blood Pressure according to the International Protocol:
The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM-7102-E) and the
Omron R3-I Plus (HEM-6022-E). Blood Pressure Monitoring 2010, 15:40-54
- Qi-Fang H, Jie W, Chang-Sheng S, Na-Na Z, Yan L and JI-Guang W. Validation of the
ANDON KD-5915 blood pressure monitor for home blood pressure monitoring according
to the European Society of Hypertension International Protocol. Blood Pressure Monitoring
2010, 5:232-234
-
Zeng WF, Huang QF, Sheng CS, Li Y and Wang JG. Validation of the Kingyield BP101H blood pressure monitor for home blood pressure monitoring
according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 15:329-331
-
Saladini F, Benetti E and Palatini P. Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol.
Blood Pressure Monitoring 2010, 15:281-284
-
Franssen PML & Imholz BPM. Evaluation of the Mobil-O-Graph new generation ABPM
device using the ESH Criteria. Blood Pressure Monitoring 2010, 15:229-231
-
Weiss W, Tolle M, Zidek W & van der Giet M. Validation of the Mobil-O-Graph:
24h-blood pressure measurement device. Blood Pressure Monitoring 2010, 15:225-
228
-
Erdem E, Aydogudu T, Akpolat T. Validation of the Medisana MTP Plus upper arm
blood pressure monitor, for self-measurement, according to the European Society
of Hypertension International Protocol revision 2010
-
Masiero S, Fania C, Palatini P. Validation of the UEBE Visomat Double Comfort
upper arm blood pressure monitor, in auscultation mode, for clinic use and
self-measurement in a general population, according to the European Society of
Hypertension International Protocol revision 2010. Blood Pressure Monitoring
2011, 16:208-210
-
Yi J, Wan Y, Pan F, Yu X, Zhao H, Shang F, Xu Y. Validation of the Medipro
Medicare 100f upper arm blood pressure monitor, for self- measurement, according
to the European Society of Hypertension International Protocol Revision 2010.
Blood Pressure Monitoring 2011, 16:197-199
-
Yarows, S. Accuracy of the HoMedics Walgreens Deluxe Arm Blood Pressure device
(WGNBPA-540) compared with auscultation in 85 individuals. Blood Pressure
Monitoring 2001, 16:200-202
|